ATEN PG98330G-AT energiedistributie 30 AC-uitgang(en) 0U Zwart

ATEN PG98330G-AT, Gemeten, Geschakeld, 0U, Driefasig, Zwart, LCD, 30 AC-uitgang(en)

Niet op voorraad

Fabrikant Aten
MPN PG98330G-AT
EAN 4710469341786
€ 1.273,00 excl. BTW
4,5 · 4,0 · Gratis verzending vanaf €250
Omschrijving
When maintaining operating uptime in a data center or server room, sustainable energy efficiency can make all the difference. The implementation of effective power management often involves improvements at both the hardware and software level. As the trend for 3-phase power grows due to its efficiency to generate, transfer, and distribute electricity, ATEN is introducing its latest PG series of PDUs, available in IEC socket configuration, that are designed with 0U rack housing to accommodate the increasing demand for power to high-density IT equipment in server rooms and data centers. Each PG98330 PDU, utilizing an ARM-Cortex A8 processor, is equipped with 30 port outlets capable of running at higher voltages, powers up all connected equipment in less than 10 seconds once plugged in, and delivers the most accurate kWh energy usage data (+/-1%) for better power consumption habits, baselines, and initiative tracking. With energy saving in mind, the PG98330 is purposed to enable lower energy consumption for best practice in a network infrastructure, while promoting up to 70.65 kg (131.4 kw equivalent of power consumption) of reduced CO2 emission, reduced electricity expenses, and lower carbon taxes to pay each year.

Energy-Saving Relay
Thanks to the built-in energy-saving relays – a subtype of electromagnetic switch – controlling a large amount of current flow becomes easy, which results in annual saving of 131.4 kW power consumption per 30-outlet PDU unit, compared with models without energy-saving relays. In addition, power distribution will remain functional and uninterrupted even when a failure occurs, enabling superior uptime to optimize system reliability.

Hydraulic-Magnetic Circuit Breaker
With the built-in hydraulic-magnetic circuit breaker in place, electricity supply can be automatically switched off to protect connected devices from getting overloaded or damaged, while maintaining stable power distribution.

Secure Locking Enhancement
The outlets can be protected with a secure lock to prevent power cords from becoming unplugged due to vibration or human errors.

Real-time Alerts via LCD Display
The illuminated LCD display can display warnings to alert users of unusual power states.

Hot-Swappable Function
The LCD console panel is hot-swappable and can be removed, replaced, or repaired without powering down a mission-critical connected load.

Dual LAN Ports for Scalable Network Setup
The PG98330 is equipped with dual LAN ports (e.g. Internet and Intranet) supporting up to 1G Ethernet connection, and can be cascaded to connect up to 64 PDUs, saving expense on installing extra network switches to incorporate network connections while sparing more rack space to accommodate more IT equipment in an expandable network.

Environment Sensors
The Sensor port enables RJ-45 connectivity to connect or daisy-chain up to 8 environment sensors for monitoring and management of temperature, humidity, airflow, differential air pressure, and leaks, featuring alerts for potential threats.

Flexible On-Site Network Operation
For quick operation, connecting a serial device to the PDU with its COM port provides another means to undertake communication via CLI commands. In addition, the same port is also functional as a PON port, available for Ethernet connection to a KN series KVM over IP Switch to centralize power management of up to 16 daisy-chained PDUs.

Networkable via WiFi
The PG98330 can be networked via connection to a USB WiFi dongle to perform DCIM, firmware upgrade, log export, quick configuration, and more.

Adjustable Power Cord for Flexible In-Rack Installation
The PG98330 comes with an adjustable power cord built in to the unit capable of 90-degree rotation to allow flexible in-rack installation, resulting in better cable organization.

DCIM Monitoring
Integrated with ATEN’s eco DC – a PC- and web-based tool for optimized Data Center Infrastructure Management (DCIM) – power distribution, energy, and environmental data from PDUs and connected devices can be monitored via a friendly web GUI for smart power management.

Colored Panel for Smarter Power Monitoring
The PG series PDUs feature a LCD console panel in default red and can be re-colored with options of yellow, purple, blue, and green through optional purchase of colored stickers. These color codes make it easier to differentiate between power feed settings and also speed up troubleshooting in case of unexpected failures.

Applications
The PG series 3-Phase PDUs are perfectly suited to server rack installation requiring energy-efficient power distribution to high-density IT equipment in a server room or data center.

  • ARM Cortex-A8 processor for flexible control methods via LAN / COM / USB / environmental sensor ports and enhanced monitoring via LCD console
  • Allows for connecting up to 64 PDU units with cascading
  • Energy-efficient relays allow operators to control a large amount of current flow for lower energy consumption
  • Precise kWh metering (+/-1% ) for better power consumption habits, baselines, and initiative tracking
Disclaimer
Beat-it.nl is niet verantwoordelijk voor eventuele fouten in de documentatie van producten. Meld foutBedankt voor uw melding!

Er ging iets mis. Probeer het opnieuw.

Specificaties

Design

PDU types*
Gemeten, Geschakeld
Soort
Driefasig
Rack-montage
Ja
Rackcapaciteit*
0U
Kleur van het product
Zwart
Beeldscherm
LCD

Poorten & interfaces

Aantal AC uitgangen*
30 AC-uitgang(en)
Stekker
IEC309
Stopcontacttypes*
C13 stekker, C19 stekker
Seriële poort(en)
2
Aantal Ethernet LAN (RJ-45)-poorten
2
Aantal USB-aansluitingen
1

Kenmerken

Doorgelust
Ja
Reset button
Ja
Snoerlengte
3 m
Ondersteunde beveiligingsalgoritmen
SMTP-AUTH, TLS
Wachtwoordbeveiliging
Ja

Beheerfuncties

Monitoring
Stroom, Stroom, Spanning
Ondersteunde netwerkprotocollen
/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, ARP, NTP, DNS, Auto Sense, Ping, SNMP V1&V2&V3, Telnet, Modbus (over TCP/IP), Wi-Fi, 802.11 a/b/g/n, IPv6, SMS
Upgraden van firmware mogelijk
Ja
Firmware kan geüpgraded worden via
Netwerk

Energie

Nominale input voltage*
230 - 400 V
AC-ingangsfrequentie
50 - 60 Hz
Stroom (max.)*
32 A
Netspanning, in bedrijf
230 V
Laad-capaciteit
22170 VA
Schakelaar
Ja

Certificaten

Certificaten van naleving
CE
Certificering
EMC

Duurzaamheid

Naleving van duurzaamheid
Ja

Eisen aan de omgeving

Bedrijfstemperatuur (T-T)
0 - 60 °C
Temperatuur bij opslag
-20 - 60 °C
Relatieve vochtigheid in bedrijf (V-V)
0 - 80 procent

Gewicht en omvang

Breedte
56 mm
Diepte
1790 mm
Hoogte
68 mm
Gewicht
8,43 kg

Inhoud van de verpakking

Gebruikershandleiding
Ja
Rekbevestigingspakket
Ja

Verpakking

Gewicht verpakking
11,2 kg
Breedte verpakking
229 mm
Diepte verpakking
1945 mm
Hoogte verpakking
179 mm
Verpakkingsvolume
79853,5 cm³

Logistieke gegevens

Land van herkomst
Taiwan
Netto gewicht kartonnen doos
11,2 kg
(Buitenste) hoofdverpakking breedte
229 mm
(Buitenste) hoofdverpakking lengte
1945 mm
(Buitenste) hoofdverpakking hoogte
179 mm
(Buitenste) hoofdverpakking brutogewicht
11,2 kg
(Buitenste) hoofdverpakking inhoud
79853,5 cm³